Brand Name : GE

Model Number : IC9445A200AB

Place of Origin : USA

MOQ : 1

Price : negotiable

Payment Terms : T/T, Western Union,paypal, Western Union

Supply Ability : 100. Ali.

Delivery Time : 5-8 work days

Packaging Details : New in original box

Certification : CE

Resistance ranges : 0 to 500 ohms,0 to 3000 ohms

Temperature sensitivity (0° to 60°C) + : +/–0.004% of reading, +/–1.5µV per °C referred to input

Maximum lead resistance : 5 ohms per lead

Update Rate : 210 ms

Power Consumption : 125 mA from +5V bus

No. of channels : 4 (3-wire and/or 4-wire RTDs)

Contact Now

GE FANUC IC9445A200AB LIMIT SWITCH Module IC9445A200AA IC9445A200AC

Product Description

The GE Fanuc IC693PWR321 is a standard power supply. This unit is a 30 watt supply that can use direct or alternating current. It operates on an input voltage of either 120/240 VAC or 125 VDC. Aside from a +5VDC output, this power supply can provide two +24 VDC outputs. One is a relay power output, which is used to power circuits on Series 90-30 Output Relay modules. The other is an isolated output, which is used internally by some modules. It can also provide external power for 24 VDC Input modules.

Just like I/O modules, this power supply is easily compatible with the Series 90-30 system and works with any CPU model. There is a limiting feature on the power supply that protects the hardware by shutting the power off if there is a direct short. The IC693PWR321 has six terminals for user connections. Like all Series 90-30 power supplies, this model is connected to the CPU performance. This enables simplex, fail-safe, and fault tolerance capabilities. The power supply also has advanced diagnostics as well as built-in smart switch fusing. This makes for high-performance and increased safety when using the unit.

Technical Specifications

Nominal Rated Voltage: 120/240 VAC or 125 VDC
Input Voltage Range: 85 to 264 VAC or 100 to 300 VDC
Input Power: 90 VA with VAC or 50 W with VDC
Load Capacity: 30 Watts
Location on Baseplates: Leftmost Slot
Communication: RS 485 Serial Port


GE FANUC IC9445A200AB LIMIT SWITCH Module IC9445A200AA IC9445A200AC

▪ Selectable resistance measurements in tenths of ohms, tenths of degrees Fahrenheit, or tenths of degrees Celsius ▪ Individual channel configuration ▪ Selectable resistance ranges: 0 – 500 ohms and 0 – 3000 ohms ▪ Selectable RTD input as resistance or temperature (Celsius or Fahrenheit) ▪ Reports high/low, under-range/over-range, open wire and input short alarms. ▪ Two data acquisition rates based on 50 Hz and 60 Hz line frequencies ▪ Configurable channel activation The module automatically performs A/D calibration at powerup. Automatic calibration is then repeated periodically to compensate for changes in the ambient temperature.

LED Indicator
The OK LED indicates module status: ▪ On green indicates normal operation ▪ Flashing green indicates boot mode or update ▪ Flashing amber indicates self-diagnostic error ▪ Off indicates no 3.3V backplane power.

GE FANUC IC9445A200AB LIMIT SWITCH Module IC9445A200AA IC9445A200AC

Using the Module in Hazardous Locations
▪ WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2;
▪ WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES.
▪ WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS.
▪ Equipment labeled with reference to Class I, Div. 2, Groups A, B, C and D, Hazardous Locations is suitable for use in Class I, Div. 2, Groups A, B, C, D or non-hazardous locations only.
▪ Equipment labeled with reference to Class I, Zone 2, Groups A, B, C and D, hazardous locations is suitable for use in Class I, Zone 2, Groups A, B, C, D or non-hazardous locations only.
▪ Be sure to read the installation instructions provided with the module and its terminal assembly. These instructions specify the use of copper conductors and wire gauge and type requirements.


Company profile:
GE FANUC IC9445A200AB LIMIT SWITCH Module IC9445A200AA IC9445A200AC

Shipping:
GE FANUC IC9445A200AB LIMIT SWITCH Module IC9445A200AA IC9445A200AC


Product Tags:

ethernet i o module

      

plc i o modules

      
Best GE FANUC IC9445A200AB LIMIT SWITCH Module IC9445A200AA IC9445A200AC wholesale

GE FANUC IC9445A200AB LIMIT SWITCH Module IC9445A200AA IC9445A200AC Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Wisdomlong Technology CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)