Brand Name : Rosemount

Model Number : 3051SFP Integral Orifice Flow Meter

Place of Origin : America

MOQ : 1

Price : negotiable

Payment Terms : T/T

Supply Ability : 100

Delivery Time : 5-8 work days

Packaging Details : New in original box

Certification : dose not supply

Brand : Rosemount

Model : 3051SFP Integral Orifice Flow Meter

Origion : America

packing : carton

lead time : 3-5 days

MOQ : 1

Contact Now

Rosemount™ 3051SFP Integral Orifice Flow Meter static pressure, process temperature, scaled variable, mass flow

The Rosemount 3051SFP Integral Orifice Flow Meter is a no-equal multivariable device customized with an integral orifice primary element. This meter run assembly provides easy installation and is engineered to facilitate highly accurate flow measurement in small line sizes (0.5 - 1.5 in. or 15 - 40 mm). This device is also engineered with built-in flow calculations for fully compensated mass flow measurements.

Specifications

Warranty Up to 1-year limited warranty
Rangedown Up to 200:1 (14:1 flow turndown)
Measurement Range Up to 2000 psi (137,89 bar) differential, Up to 3626 psi (250,00 bar) static
Line Size

0.5 to 1.5 in. (15 to 40 mm)

Output

Differential pressure, static pressure, process temperature, scaled variable, mass flow, volumetric flow, energy flow

Communication Protocol

4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus
Process Wetted Material 316 SST

Diagnostics

Basic Diagnostics, Power Advisory Diagnostics, Advanced Diagnostics

Certifications/Approvals

SIL 2/3 certified to IEC 61508 by an independent 3rd party, NACE, hazardous location, see full specs for complete list of certifications

Features

  • Designed with built-in flow calculations for direct reporting of fully-compensated mass flow
  • Advanced diagnostics provide diagnostic coverage to detect abnormal process conditions and electrical loop issues
  • Primary element integrated in a meter run for ease of installation
  • Suitable for small line sizes 0.5- 1.5 in. (15 - 40 mm) for optimal flow measurement accuracy and repeatability
  • Callendar-Van Dusen sensor matching improves temperature accuracy enabling best-in-class flow calculations
  • Ultra for Flow performance class enables optimized flow measurement with a ±0.04% of reading accuracy
  • All-welded, SuperModule™ design offers industry-leading accuracy in harsh environments and applications
  • Flowmeters come fully configured, leak-tested and ready to install right out of the box for fast installation
  • Flowmeter technology eliminates unnecessary pipe penetrations for an integrated, trouble-free solution
  • SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations

CHALLENGE

In order to measure large flow ranges and adapt to changing process conditions, it is often necessary to stack multiple transmitters or trade out orifice plates. This leads to increased costs, inventory, and process downtime.

OUR SOLUTION

RosemountTM Ultra for Flow (UFF) technology improves transmitter performance in high turndown applications. A single Rosemount UFF unit is able to capture the entire range, eliminating the need to stack transmitters or change out primary elements. Rosemount UFF also reduces inventory by allowing users to standardize on a single transmitter for any application. Rosemount Ultra for Flow is a transmitter accuracy class, based on a percentage of DP reading, where accuracy increases as flow rate turns down. In contrast, percent of span transmitters experience large errors when flow rate turns down.

Key Innovations

• .04% of reading specification over a 14:1 turndown

• Includes a 15 year warranty and 15 year stability

• Ultra for Flow accuracy class is exclusive to EmersonTM

Rosemount™ 3051SFP Integral Orifice Flow Meter static pressure, process temperature, scaled variable, mass flow

Rosemount™ 3051SFP Integral Orifice Flow Meter static pressure, process temperature, scaled variable, mass flow


Product Tags:

high temperature differential pressure transmitter

      

absolute pressure transmitter

      
Best Rosemount™ 3051SFP Integral Orifice Flow Meter static pressure, process temperature, scaled variable, mass flow wholesale

Rosemount™ 3051SFP Integral Orifice Flow Meter static pressure, process temperature, scaled variable, mass flow Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Wisdomlong Technology CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)